The crack appears in January and the cause was set in August. Timber that leaves at 11% and lands in a heated room at 22% has to shrink somewhere.

Part of the timber guide — Chair Timber: What Actually Holds a Guest Up

The room is drier than the kiln

European beech moves high — about 0.4% per 1% moisture change across the grain. In a dining room held at 21 °C and 25% relative humidity through a northern winter, a 60 mm rail loses about 1 mm of width. Multiply that by every joint in the frame and something has to give.

What gives is the weakest point: the glue line at a mitre, a back post with a pin hole through it, or the end of a tenon that was not sealed. The crack is always at a stress riser, never in the middle of a clean part.

Packing moisture is the only number that matters

We pack at 8–10% at packing. Not because it is a standard, but because a container crossing the tropics can push 8% timber to 13% and back; starting at 8–10% leaves room for the round trip. Timber packed at 8% gains a little in the container and settles in the room. Timber packed at 12% has nowhere to go but into shrinkage.

The reading taken on the outside of a rail is two points low. Ask for a cut test on one piece per kiln charge — cut 50 mm off, measure the fresh face. That is the figure to put on the inspection record.

Three things the workshop controls

End sealing. Cut ends get wax or a sealer within the shift. End grain takes on and gives off moisture eight to ten times faster than the face, and an unsealed tenon end is a crack waiting for a dry week.

Grain run-out. Parts machined with the grain running out at 1 in 8 are splits under shrinkage. Sorting the cutting list so run-out stays under 1 in 12 costs a little yield and saves the frame.

Pin placement. One 6 mm pin 15 mm from the end of a rail halves the section. Move it to 25 mm and the same joint stops being the crack site.

What to do when a frame arrives dry

Leave it in the room, in the cartons, for 72 hours before unpacking. Letting it equalise inside the packaging keeps the change slow and even. Unpacking into a hot dry lobby on day one is how a delivery develops cracks before installation.

Then check a sample with a meter and log the reading. If it is under 7%, the frames were packed too dry for the destination and the next order should be packed at the top of the range. The timber guide has the kiln schedules and the moisture table behind this, and moisture content at packing covers the inspection side.